產(chǎn)品詳細(xì)介紹:
產(chǎn)品特點:
NDJ-1/NDJ-4旋轉(zhuǎn)式粘度計各種牛頓液體黏度和非牛頓液體表現(xiàn)黏度。
適用于測定流體和半流體的黏度和流度性。
用于染料,油化,油墨,化妝品,油脂等流體
的動力黏度等。
NDJ-1型旋轉(zhuǎn)式粘度計使用說明書
NDJ-1 Rotational Viscometer Instruction Manual
產(chǎn)品應(yīng)用:Application
本產(chǎn)品廣泛應(yīng)用于測定油脂,油漆,塑料,食品,藥物,膠粘劑,化妝品等各種流體的粘性阻力與液體的粘度。在使用時按照說明書的要求進(jìn)行安裝和測量工作。
NDJ-1 Rotational Viscometer is a novel instrument to be used in measuring the viscous resistance and the absolute viscosity of fluid.It is widely applicable to determine the viscosity of various kinds of fluids, such as grease, paint, plastics, food products, pharmaceuticals, bonding agent, etc.
1.主要技術(shù)規(guī)格:
測量范圍:10~ 105 map.s
轉(zhuǎn)速: 6,12,30,60 Spin/minute
測量誤差:±5%(牛頓液體)
電源: 220V±10V,50Hz
Main Technical Specification:
Range:Medium Viscosity 10-100,000mPa.s
Low Viscosity 0.1-100mPa.s
Medium Viscosity 4 Rotors of No.s 1,2,3 and 4.
Low Viscosity 1 Rotor of No.0
Speed of Rotor:6rpm,12rpm,30rpm and 60rpm.
Measurement tolerance: ±5%(Newtonian fluid)
Power Supply:220V±10%V.50Hz
2.安裝:
1) 從包裝箱中取出機箱底座與支柱。
2) 將三只水平調(diào)整腳旋入底座螺絲孔中(圖一)
3) 主機安裝:
a. 旋松機箱中螺釘取出主機。
b. 旋松手柄固定鈕,將電源線嵌入手柄夾頭槽內(nèi)
(圖二1)。
c. 將手柄穿入夾頭槽底圓孔中(圖二2)
d. 旋緊手柄固定鈕夾緊手柄,并使主機基本保持水平(圖二3)
e. 拆除指針主桿上的橡皮圈和主機下端的黃色包裝套圈(圖三)。
警告!在未拆除上述兩項前不可通電開機,否則將損壞機器。
f. 接上電源,調(diào)整水平調(diào)整腳(圖四)
,使水準(zhǔn)器中水平泡居于中心圓圈中(圖五)。
Installation:
1) Take out the support stand, column from the packing box.
2) Screw the column into the hole at the rear of the support stand with the teethed side facing the front of the support stand. Tighten the 3 adjustments underneath the stand support.
3) Installation of Main Body:
a. Take out of the main body and loose the screw.
b. Loose the fixed button and embed the power cord into the groove of the clamp.
c. Let the handle get through the hole of groove of the clamp.
d. Tighten the fixing screw on lever and keep the main body horizontal.
e. Remove the rubber band on the indicator control lever, release the yellow screw at the lower end of the instrument and lastly remove the yellow packing ring.
Warning!
Do not power on before the 2 operations above, otherwise damage will be caused.
f. Power on, make adjustment of the support stand and make sure the leveling bubble is in the center.
3. 操作:
1) 首先將保護架右旋上儀器下端。
2) 準(zhǔn)備被測液體,選擇直徑>or=70mm 的圓柱型容器。
3) 按測量要求的精度,準(zhǔn)確控制被測液體的溫度
4) 估計被測液體黏度值的大致范圍參考量程表選好轉(zhuǎn)子號,并將轉(zhuǎn)子左旋入連接螺桿(圖4).然后旋轉(zhuǎn)升降鈕(圖5),使儀器慢慢地下降,逐漸浸入測量液體中,直至轉(zhuǎn)子液面標(biāo)志和液面平為止。(圖4)按下指針鎖定桿,開啟電源開關(guān),放開指針鎖定桿,使轉(zhuǎn)子在液體中旋轉(zhuǎn),一般20~30秒的運轉(zhuǎn),待指針趨于穩(wěn)定。按下指針鎖定桿,使讀數(shù)固定下來,再關(guān)閉電機,使指針停在讀數(shù)窗范圍內(nèi),直接讀出數(shù)據(jù)。當(dāng)電機關(guān)停后,如指針不處于讀書窗內(nèi),應(yīng)繼續(xù)按住指針鎖定桿,反復(fù)開啟和關(guān)閉電機,使指針處于讀數(shù)窗內(nèi)。如選用6和12轉(zhuǎn)/分時,可直接讀取讀數(shù),不需鎖定指針。
5) 讀數(shù)指針一般在30~90分度之間為佳,否則可變換轉(zhuǎn)子號和轉(zhuǎn)速達(dá)到這個要求。
6) 當(dāng)不能預(yù)知被測液體粘度值時,應(yīng)試用由小到大的轉(zhuǎn)子和轉(zhuǎn)動變速鈕(圖5),由慢到快的變化轉(zhuǎn)速順序來測定粘度值。
Operation:
1) Firstly,Spin the protector pole to right just right under the instrument.
2) Prepare the fluid to be measured ,put it in a beaker or cylindrical container with its diameter not less than 70mm.
3) According to the requested precision of measurement, the temperature of the fluid to be measured should be precisely under control.
4) First estimate the approximate range of viscosity of the fluid to be measured, then select the appropriate rotor and speed according to table of range. Screw the selected rotor into the connecting worm(Turn left to install and right to remove).Turn the elevation knob, slowly lower the instrument, the rotor will gradually dip into the fluid surface, then adjust the leveling speed changing knob making the required speed upward to align with the indication point for speed, release the indicator control rod causing the rotor to rotate in the fluid. After several rotation(Generally 20-30seconds) until the indicator tends to be stable(or make readings at specified time).Press indicator control rod(Caution: 1. Do not use excessive force. 2.When the speed is quite slow, it is not necessary to use control rod. The readings can be directly made), causing the reading to settle, switch off the motor, the indicator will stay at the readout window and then reading can be taken. After the motor has switched off but the indicator does not stay at the readout window, press the indicator control rod continuously and repeatedly switch off the motor. After several practices the user will skillfully manage the technique of keeping the indicator too stay in the window for reading.
5) When the value indicated by the indicator is too high or too low, change the rotor or speed so the reading is preferable range of 30-90 graduation.
6) When the approximate viscosity of the fluid to be measured is difficult to estimate, suppose a higher viscosity first, then try the rotor of lower No. to higher No. and lower speed to higher speed. The principle is that for the fluid of high viscosity select small rotator and low speed. For the fluid of low viscosity select large rotor and high speed.
4. 注意事項:
1) 本儀器使用于常溫環(huán)境下 10 ~ 30 ℃
2) 測定時裝上保護架,否則測定粘度將因容器的直徑變化而變化。
3) 轉(zhuǎn)子在安裝和拆除時應(yīng)將轉(zhuǎn)子連接螺桿向上抬起,避免轉(zhuǎn)軸軸尖碰損,浸入液體時避免氣泡粘附于轉(zhuǎn)子上。
4) 儀器不得測放或倒放,特別是在裝上轉(zhuǎn)子時。
5) 裝上轉(zhuǎn)子后,不要在未浸入液體的情況下,開機旋轉(zhuǎn)。
6) 每次使用完畢小心拆下轉(zhuǎn)子,*清洗,用吹風(fēng)機吹干,垂直安放在轉(zhuǎn)子架上。
7) 搬運儀器時應(yīng)裝上黃色包裝套圈和橡皮圈鎖定指針鎖定桿。
8) 直接測定被測液體的,不要以恒溫槽的溫度代替被測液體的溫度。
9) 在測試中非牛頓液體的表現(xiàn)粘度往往因切變速率和測定時間長短等因素的不同而變化,屬正常情況,非儀器故障。
10) 嚴(yán)格按照使用要求操作使用。
Points for Attention:
This instrument should be used in regular temperature(Normally 10-30 ?C).
The protector should be applied in the course of measurement, otherwise the viscosity will vary with the diameter of the container.
Care should be taken in installing and removing the rotor. To install and remove the rotor the connecting worm should be slightly lifted to avoid he shaft tip damaged.
When the rotor is installed, the instrument should not be placed on its side or upside down.
After installation of rotor do not power on in the case that the rotor is not dipping into the fluid.
After each operation, clean the rotor immediay (don't clean the rotor when it is on the instrument). After cleaning, put the rotor on the rotor rack properly.
When moving or transporting the instrument, use a rubber band to wrap the indicator control rod and keep it tightening, sleeve it into the yellow packing ring and lift the connecting worm.
Precisely control the temperature of the fluid to be measured.
Most of the high viscosity fluid, such as suspension, emulsion, high polymer, etc., are usually "Non-Newtonian fluid", their variation of viscosity is according to the shear rate and change of time. Therefore measurement under different rotor, speed and time may give non-uniform results. This is normal, and it is no the fault of the instrument.
Strictly adhere to the operation instructions for measurement.
系 數(shù) 和 誤 差 修 正
1.測定時指針在刻度盤上的指示值乘上系數(shù)表中的系數(shù)值,得到測量液的粘度值。
既:η(mpa.s)=k * a 例:選用2號轉(zhuǎn)子, 轉(zhuǎn)速=20轉(zhuǎn)/分 | |||||||||||||
k = 系數(shù) 查系數(shù)表k=10 | |||||||||||||
a = 指針讀數(shù)值 a=指針讀數(shù)值為:68 | |||||||||||||
η = 粘度值 η(mpa.s)=10*86=680 |
2.頻率誤差修正(運用正常電網(wǎng)一般不用修正)
名義頻率 | |||||||||||||
實際粘度= 指示粘度 * —————— | |||||||||||||
實際頻率 |
量 程 表 和 系 數(shù) 表
量程表 | 系數(shù)表 | |||||||||
轉(zhuǎn)子 | 轉(zhuǎn)/分 | 轉(zhuǎn)子轉(zhuǎn)/分 | 60 | 30 | 12 | 6 | ||||
60 | 30 | 12 | 6 | |||||||
1 | 100 | 200 | 500 | 1000 | 1 | 1 | 2 | 5 | 10 | |
2 | 500 | 1000 | 2500 | 5000 | 2 | 5 | 10 | 25 | 50 | |
3 | 2000 | 4000 | 10000 | 20000 | 3 | 20 | 40 | 100 | 200 | |
4 | 10000 | 20000 | 50000 | 100000 | 4 | 100 | 200 | 500 | 1000 |
成 套 明 細(xì) 表
1.主機 1臺 5.水平調(diào)整螺釘 3只 | |||||||||||||
2.1、2、3、4號轉(zhuǎn)子 各1只 6.說明書 1份 | |||||||||||||
3.保護架 1只 7.合格證 1份 | |||||||||||||
4.支架 1套 |
《參考資料》
“牛頓型流體” 和 “非牛頓型流體”
流體可分為“牛頓型”如:硅油、機油、甘油等。“非牛頓型”如:油漆、乳膠、橡膠、塑料、涂料、膠粘劑等。
在測量過程中如果被測流體的溫度,環(huán)境溫度,樣品杯口徑大小和是否安裝保護架等情況的變化下,則“牛頓型”和“非牛頓型”流體及粘度值都會隨之變化。如果以上幾個條件都不變,但測量的轉(zhuǎn)子,測量速度和測量時間變化,對于“牛頓型”的測量結(jié)果是基本接近的,其粘度值稱之粘度。但對于“非牛頓型”測量結(jié)果是會變化的。也就是說在測量“非牛頓型流體”時轉(zhuǎn)子和速度是不能互換的,其粘度值稱之表現(xiàn)粘度。因此在測量“非牛頓型”時要根據(jù)自己樣品的情況規(guī)定轉(zhuǎn)子,轉(zhuǎn)速及測量時間。以免誤解為粘度不準(zhǔn)。
請輸入賬號
請輸入密碼
請輸驗證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),化工儀器網(wǎng)對此不承擔(dān)任何保證責(zé)任。
溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。