| | | Safety light curtain | | SLC14-1050/130/151 | |
| |
|
| | | | | Detection range up to 5 m, Resolution 14 mm (finger protection), Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Start/Restart disable , Effective detection range: 0.2 ... 5 m, Operating voltage: 24 V DC (-30 %/+25 %), Connection: Emitter: M12 connector, 4-pin Receiver: M12 connector, 8-pin, Optical resolution: 14 mm, Operating mode: can be selected with or without start/restart disable, Safety output: 2 separated fail safe semiconductor outputs | |
|
| | |
| | | Safety light curtain | | SLC14-1200/31/130 | |
| |
|
| | | | | Sensing range up to 5 m, Resolution 14 mm (finger protection), Protective field height up to 1800 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Effective detection range: 0.2 ... 5 m, Operating voltage: 24 V DC (-30 %/+25 %) / 24 V AC (-20 %/+10 %), Connection: M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 , Optical resolution: 14 mm | |
|
| | |
| | | Safety light curtain | | SLC14-300/129/151 | |
| |
|
| | | | | Detection range up to 5 m, Resolution 14 mm (finger protection), Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Protection degree IP67, Effective detection range: 0.2 ... 5 m, Operating voltage: 24 V DC (-30 %/+25 %), Connection: Emitter: M12 connector, 4-pin Receiver: M12 connector, 8-pin, Optical resolution: 14 mm, Operating mode: can be selected with or without start/restart disable, Safety output: 2 separated fail safe semiconductor outputs | |
|
| | |
| | | Safety light curtain | | SLC14-450/129/151 | |
| |
|
| | | | | Detection range up to 5 m, Resolution 14 mm (finger protection), Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Protection degree IP67, Effective detection range: 0.2 ... 5 m, Operating voltage: 24 V DC (-30 %/+25 %), Connection: Emitter: M12 connector, 4-pin Receiver: M12 connector, 8-pin, Optical resolution: 14 mm, Operating mode: can be selected with or without start/restart disable, Safety output: 2 separated fail safe semiconductor outputs | |
|
| | |
| | | Safety light curtain | | SLC30-1050 | |
| |
|
| | | | | Sensing range up to 15 m , Resolution 30 mm (hand protection), Protective field height up to 1800 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Effective detection range: 0.2 ... 15 m, Operating voltage: 24 V DC (-30 %/+25 %), Connection: M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 , Optical resolution: 30 mm, Operating mode: can be selected with or without start/restart disable | |
|
| | |
| | | Safety light curtain | | SLC30-150-S | |
| |
|
| | | | | Detection range up to 15 m , Resolution 30 mm (hand protection), Protection field height up to 1650 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Effective detection range: 0.2 ... 15 m, Operating voltage: from master, Connection: M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm 2 , Optical resolution: 30 mm, Operating mode: in the master, Safety output: in the master, Protection field height: 150 mm | |
|
| | |
| | | Safety light curtain | | SLC30-750/31 | |
| |
|
| | | | | Sensing range up to 15 m , Resolution 30 mm (hand protection), Protective field height up to 1800 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Effective detection range: 0.2 ... 15 m, Operating voltage: 24 V DC (-30 %/+25 %) / 24 V AC (-20 %/+10 %), Connection: M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 , Optical resolution: 30 mm | |
|
| | |
| | | Safety light curtain | | SLC60-1200 | |
| |
|
| | | | | Sensing range up to 15 m , Resolution 60 mm , Protective field height up to 1800 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Effective detection range: 0.2 ... 15 m, Operating voltage: 24 V DC (-30 %/+25 %), Connection: M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 , Optical resolution: 60 mm, Operating mode: can be selected with or without start/restart disable | |
|
| | |
| | | Safety light curtain | | SLC90-600/31 | |
| |
|
| | | | | Sensing range up to 15 m , Resolution 90 mm, Protective field height up to 1800 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Effective detection range: 0.2 ... 15 m, Operating voltage: 24 V DC (-30 %/+25 %) / 24 V AC (-20 %/+10 %), Connection: M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 , Optical resolution: 90 mm, Operating mode: can be selected with or without start/restart disable | |
|
| | |
| | | Safety light curtain | | SLCS30 Series | |
| |
|
| | | | | Resolution 30 mm (hand protection), Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Emitter unit: connector M12 x 1, 4-pin Receiver: 8-pin, M12 x 1 connector Cable cross section min. 0.25 mm2 Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable |
|
|