JZ-6029型硫化儀說明書
1、揚(yáng)州精卓硫化儀客戶使用須知············································3
2、揚(yáng)州精卓硫化儀包裝、運(yùn)輸及安裝·······································4
2、揚(yáng)州精卓硫化儀簡介及概述·············································5
3、揚(yáng)州精卓硫化儀本機(jī)特點(diǎn)················································5
4、揚(yáng)州精卓硫化儀技術(shù)指標(biāo)及規(guī)格··········································5
5、揚(yáng)州精卓硫化儀構(gòu)造與原理··············································6
6、揚(yáng)州精卓硫化儀操作····················································7
7、揚(yáng)州精卓硫化儀試驗(yàn)····················································9
8、揚(yáng)州精卓硫化儀不同工作窗口功能介紹···································12
9、揚(yáng)州精卓硫化儀軟件的安裝············································13
10、揚(yáng)州精卓硫化儀維護(hù)和保養(yǎng)············································14
11、揚(yáng)州精卓硫化儀常見故障的排除······································
a、請(qǐng)不要將計(jì)算機(jī)移做他用,以免沖突程序或帶進(jìn)病毒感染使的儀器不能正常工作。胡亂使用移動(dòng)盤帶進(jìn)病毒感染造成機(jī)器不能正常工作。
c、電網(wǎng)波動(dòng)太大引起設(shè)備損壞。
d、接錯(cuò)電源(如將AC380V電壓接入本設(shè)備)。
e、雷擊(雷電天氣時(shí)避免使用本儀器,或者有可靠的僻雷措施方可使用)。
h、經(jīng)過培訓(xùn)已會(huì)使用,但是過段時(shí)間用戶操作人員離開而照成設(shè)備不會(huì)使用,需要我公司再次培訓(xùn)的。
i、遇到重大自然災(zāi)害等不可抗拒力而造成機(jī)器損壞的。
運(yùn)輸過程中不得將儀器倒置,小心輕放,嚴(yán)禁劇烈碰撞。嚴(yán)禁浸水。
1.3.1 揚(yáng)州精卓硫化儀開箱并檢查包裝內(nèi)容
儀器放在平臺(tái)上應(yīng)留有足夠的空間。調(diào)整四顆底腳螺栓調(diào)節(jié)水平。
從空壓機(jī)接二連體(減壓閥)入口,使氣體進(jìn)入減壓閥。減壓閥接有兩端輸出,一端
接壓力表,另一端接控制閥??刂崎y兩個(gè)輸出,分別接大氣缸的上端入口和下端入口與開合門氣缸的接入口。
1.3.4 揚(yáng)州市精卓試驗(yàn)機(jī)械廠電器的安裝
注意:配電容量應(yīng)滿足本儀器要求,當(dāng)電網(wǎng)波動(dòng)較大時(shí),應(yīng)加配容量在1.0 KVA左右的正弦交流穩(wěn)壓電源。
硫化儀安裝步驟如下:
b. 將電腦、打印機(jī)與主機(jī)之間的各接插件插好;
c. 連接主機(jī)、電腦、打印機(jī)的~220V電源;
d. 連接好主機(jī)與空壓機(jī)之間的壓縮氣源(不得漏氣)。經(jīng)仔細(xì)檢查,確認(rèn)無誤后方可接通~220V電源。
e. 插上隨機(jī)配備軟件U盤鎖,使用過程中切勿遺失,否則無法正常工作。
注意:準(zhǔn)備工作結(jié)束,儀器運(yùn)行前,請(qǐng)仔細(xì)閱讀并熟悉以下內(nèi)容!
3.揚(yáng)州精卓硫化儀 本機(jī)特點(diǎn)
3.2全密閉模腔結(jié)構(gòu),通過密封圈將轉(zhuǎn)動(dòng)腔體和殼體進(jìn)行密閉。密閉型模腔重復(fù)性能*一致。
3.3采用控制模塊直接控溫,比溫控儀控溫精度高10倍,達(dá)0.01℃。
3.4具有功能強(qiáng)大的數(shù)據(jù)庫,可以進(jìn)行統(tǒng)計(jì)、分析、存儲(chǔ)、對(duì)比等功能,人性化設(shè)計(jì)、操作方便。
4.揚(yáng)州精卓硫化儀 技術(shù)指標(biāo)及規(guī)格
4.1執(zhí)行標(biāo)準(zhǔn):ASTMD5289-95 ISO6502-1999(E) GB/T16584-1996
4.3 測溫精度:100--200℃時(shí),±0.01℃
4.4控溫穩(wěn)定度:100--200℃時(shí),±0.1℃
4.5設(shè)定范圍:0--200℃;設(shè)定zui小單位:0.1℃
4.8自動(dòng)量程切換:根據(jù)實(shí)際力矩自動(dòng)增加和減少(5-20N.m)
4.10電源:~220V±10%,50±1Hz,必須要良好接地
4.11壓縮空氣:0.4Mpa 由氣動(dòng)調(diào)節(jié)閥控制
4.12擺動(dòng)頻率:100次/分鐘(約1.7HZ)
4.13環(huán)境溫度:常溫--40℃,相對(duì)濕度<80%(空氣中不含腐蝕性氣體)
無轉(zhuǎn)子硫化儀是一種智能型的儀器,它融合了機(jī)械與電兩種原理。由以下幾個(gè)部分組成:
5.1.1 機(jī)械部分:由外殼、上下模、1.7HZ擺動(dòng)機(jī)構(gòu)、測力傳感器組成;
5.1.2空氣控制系統(tǒng):由開合模的氣缸、電磁閥,門控系統(tǒng)和空壓機(jī)四部分組成;
5.1.3電控系統(tǒng):由測溫系統(tǒng)和控溫系統(tǒng)組成;
揚(yáng)州精卓硫化儀儀器及控制系統(tǒng)結(jié)構(gòu)圖見附圖1
5.2 揚(yáng)州精卓硫化儀設(shè)計(jì)原理
打印報(bào)告上的數(shù)據(jù)所表示的內(nèi)容如下:
TS1(早期硫化時(shí)間、焦燒時(shí)間):ML+0.1Nm 即在ML的基礎(chǔ)上增加0.1N·m力矩時(shí)所對(duì)應(yīng)的時(shí)間,以分鐘計(jì)算。
TS2(早期硫化時(shí)間、焦燒時(shí)間):ML+0.2Nm 即在ML的基礎(chǔ)上增加0.2N·m力矩時(shí)所對(duì)應(yīng)的時(shí)間,以分鐘計(jì)算。
T10(初始硫化時(shí)間):ML+(MH-ML)×10% 既轉(zhuǎn)矩達(dá)到此值時(shí)所對(duì)應(yīng)的時(shí)間,以分鐘計(jì)算。
T30(能評(píng)定的硫化時(shí)間):ML+(MH-ML)×30% 既轉(zhuǎn)矩達(dá)到此值時(shí)所對(duì)應(yīng)的時(shí)間,以分鐘計(jì)算。
T50(能評(píng)定的硫化時(shí)間):ML+(MH-ML)×50% 既轉(zhuǎn)矩達(dá)到此值時(shí)所對(duì)應(yīng)的時(shí)間,以分鐘計(jì)算。
T70(能評(píng)定的硫化時(shí)間):ML+(MH-ML)×70% 既轉(zhuǎn)矩達(dá)到此值時(shí)所對(duì)應(yīng)的時(shí)間,以分鐘計(jì)算。
T90(經(jīng)常采用的*硫化時(shí)間):ML+(MH-ML)×90% 既轉(zhuǎn)矩達(dá)到此值時(shí)所對(duì)應(yīng)的時(shí)間,以分鐘計(jì)算。
VC(硫化速度指數(shù)):VC=100/(T90-TS1)
a. 環(huán)境溫度:0℃—40℃ 相關(guān)濕度:<80%
c. 電壓要求:220V±10% 電流頻率:50HZ±1HZ
e. 決不允許把計(jì)算機(jī)移作他用,以免沖突程序或帶進(jìn)病毒,而使儀器不能正常工作。
f. 在不熟悉硫化儀操作和性能前,請(qǐng)不要輕易操作,以免引起錯(cuò)誤而降低儀器的精度。
6.3揚(yáng)州精卓硫化儀主機(jī)面板操作鍵功能簡介:
在確認(rèn)連接無誤后,即可通電。通電順序:顯示器→打印機(jī)→電腦→主機(jī)。
a、 按 “開模/合模”鍵,相應(yīng)指示燈亮,開啟合模或關(guān)閉模腔的工作門。此鍵在開模、合模狀態(tài)之間轉(zhuǎn)換。
c、 按 “電機(jī)”鍵,相應(yīng)指示燈亮,電機(jī)轉(zhuǎn)動(dòng)。(調(diào)試時(shí)用,工作時(shí)無需按此鍵)
d、 按 “加熱”鍵,相應(yīng)指示燈亮,模腔進(jìn)行加熱。再按“加熱”鍵,指示燈滅,模腔停止加熱。
7. 試驗(yàn)(試驗(yàn)前請(qǐng)?jiān)敿?xì)熟悉操作步驟,很重要)
7.1連接好主機(jī)、電腦、打印機(jī)、空氣壓力等準(zhǔn)備工作。
嚴(yán)禁設(shè)定以下時(shí)間值:88、117、118
a. 在主畫面時(shí)當(dāng)上模或下模的溫度顯示-246.84℃時(shí)應(yīng)立即關(guān)掉電源,否則會(huì)損壞加熱盤或測控模塊,后果嚴(yán)重。
b. 嚴(yán)禁設(shè)定以下溫度值:7、8、11、12、13、14、17、21、22、23。
7.14揚(yáng)州精卓硫化儀軟件刪除歷史數(shù)據(jù)
a、“歷史數(shù)據(jù)”進(jìn)入數(shù)據(jù)庫
b、要?jiǎng)h除的數(shù)據(jù)的ID號(hào)
c、“去鎖”,再要?jiǎng)h除的數(shù)據(jù)的ID號(hào)
d、“刪除”,再要?jiǎng)h除的數(shù)據(jù)的ID號(hào),該數(shù)據(jù)即被刪除。
8.1 主工作窗口:實(shí)驗(yàn)時(shí)間、實(shí)驗(yàn)溫度設(shè)定工作窗口,如前面所述。
c. 所要讀出的數(shù)據(jù)前面的ID號(hào),此時(shí)該編號(hào)膠料的試驗(yàn)數(shù)據(jù)及曲線即顯示在畫面上;
d. 如需打印,只要“打印”即可。(此時(shí)打印的曲線圖中無溫度曲線)。
刪除: a、“歷史數(shù)據(jù)”進(jìn)入數(shù)據(jù)庫
b、要?jiǎng)h除的數(shù)據(jù)的ID號(hào)
c、“去鎖”,再要?jiǎng)h除的數(shù)據(jù)的ID號(hào)
d、“刪除”,再要?jiǎng)h除的數(shù)據(jù)的ID號(hào),該數(shù)據(jù)即被刪除。
如在“加鎖”狀態(tài)下進(jìn)行刪除操作,此數(shù)據(jù)前面的ID方塊顏色變成紅色,表示此操作無效。
關(guān)閉:如果操作完成后,需要關(guān)閉數(shù)據(jù)庫,關(guān)閉即可,此時(shí)畫面返回到主工作窗口。
9.1、打開我的電腦\E:\硫化儀安裝盤\軟件鎖文件夾,雙擊“Sentinel protection Install”圖標(biāo)安裝軟件鎖軟件。
9.3、打開我的電腦\E:\硫化儀安裝盤\中文版文件夾,雙擊“setup”圖標(biāo)后確定進(jìn)行軟件安裝
9.4、安裝圖標(biāo)將硫化儀軟件安裝在默認(rèn)的C:\profram files\硫化儀測控軟件檢索統(tǒng)計(jì)版目錄下
9.7、在安裝過程中跳出“重新安裝應(yīng)用程序可能會(huì)修復(fù)此問題”窗口,“是”確定
9.8、在安裝過程中跳出“注冊(cè)文件時(shí)出錯(cuò)”窗口,“忽略”確定
9.9、連續(xù)重復(fù)7、8步驟直至跳出“安裝成功”窗口,“確定”軟件安裝成功
9.10、打開我的電腦\E:\硫化儀參數(shù)號(hào)文件夾,將該文件夾中的全部文件復(fù)制并覆蓋到C:\profram files\硫化儀測控軟件檢索統(tǒng)計(jì)版目錄下
9.12 開始菜單找到所有程序/硫化儀/硫化儀測控軟件檢索統(tǒng)計(jì)版,鼠標(biāo)右鍵出現(xiàn)發(fā)送到/桌面快捷方式,左鍵發(fā)送到桌面
10. 揚(yáng)州精卓硫化儀維護(hù)和保養(yǎng)
10.1. 儀器的內(nèi)外部必須保持清潔,禁止使用腐蝕性的溶液或汽油清洗儀器表面。
10.2. 每隔一、兩個(gè)星期用軟布沾機(jī)油清洗兩根導(dǎo)柱;
10.3每次做完試驗(yàn),要清理模具型腔里的橡膠殘?jiān)?/a>
10.4機(jī)內(nèi)氣動(dòng)聯(lián)件每工作三個(gè)月用煤油清洗一次。
10.13 揚(yáng)州精卓硫化儀本機(jī)故障時(shí)先檢查保險(xiǎn)絲是否熔斷,如有熔斷,因先分析何種原因引起,找出原因后方可換上新保險(xiǎn)絲。
10.14當(dāng)保險(xiǎn)絲均完好時(shí),再檢查接插件是否有松動(dòng)現(xiàn)象。
10.15檢查開關(guān)電源是否符合標(biāo)稱值,即輸出應(yīng)為+5V、+12V -12V,如有異常,立即關(guān)閉。
10.16電路板的維修原則采用整塊調(diào)換的方法,用戶在購機(jī)時(shí)可另購備板,保修期內(nèi)嚴(yán)禁亂動(dòng),否則后果自負(fù)!
10.17打印機(jī)易損件應(yīng)經(jīng)常更換。
10.18本儀器不用時(shí)必須每周加電一次,加電時(shí)間不得少于15分鐘,以保持電子元件處于正常狀態(tài)。
10.19線路板、測控模塊用戶一般不用拆,有問題應(yīng)及時(shí)與本廠。
c. 氣壓應(yīng)符合規(guī)定壓力
揚(yáng)州精卓硫化儀不明原因的誤動(dòng)作
a. 現(xiàn)場周圍有頻繁動(dòng)作的大功率用電設(shè)備
c. 有磁場或電磁波干擾
a. 儀器與大功率設(shè)備盡量避開
c. 機(jī)器可靠接地
揚(yáng)州精卓硫化儀模腔盤不加熱
a. 上下模都不加熱時(shí),加熱開關(guān)未按下
b. 單只不加熱,加熱盤電源插頭松或固態(tài)繼電器燒壞
c. 換新的電熱盤
各動(dòng)作正常,但不打印
a. 打印聯(lián)絡(luò)線插頭松
b. 見打印機(jī)說明書
揚(yáng)州精卓硫化儀主機(jī)與電腦連不上(畫面中無溫度、力矩值)
a. 連接線松掉
d. 關(guān)閉電源后開機(jī)
個(gè)別動(dòng)作不對(duì)該動(dòng)作開關(guān)損壞更換新開關(guān)
相關(guān)產(chǎn)品
免責(zé)聲明
- 凡本網(wǎng)注明“來源:化工儀器網(wǎng)”的所有作品,均為浙江興旺寶明通網(wǎng)絡(luò)有限公司-化工儀器網(wǎng)合法擁有版權(quán)或有權(quán)使用的作品,未經(jīng)本網(wǎng)授權(quán)不得轉(zhuǎn)載、摘編或利用其它方式使用上述作品。已經(jīng)本網(wǎng)授權(quán)使用作品的,應(yīng)在授權(quán)范圍內(nèi)使用,并注明“來源:化工儀器網(wǎng)”。違反上述聲明者,本網(wǎng)將追究其相關(guān)法律責(zé)任。
- 本網(wǎng)轉(zhuǎn)載并注明自其他來源(非化工儀器網(wǎng))的作品,目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點(diǎn)和對(duì)其真實(shí)性負(fù)責(zé),不承擔(dān)此類作品侵權(quán)行為的直接責(zé)任及連帶責(zé)任。其他媒體、網(wǎng)站或個(gè)人從本網(wǎng)轉(zhuǎn)載時(shí),必須保留本網(wǎng)注明的作品第一來源,并自負(fù)版權(quán)等法律責(zé)任。
- 如涉及作品內(nèi)容、版權(quán)等問題,請(qǐng)?jiān)谧髌钒l(fā)表之日起一周內(nèi)與本網(wǎng)聯(lián)系,否則視為放棄相關(guān)權(quán)利。